QUALITY MANAGEMENT
Fishbone Analysis - Weld Penetration
New CAPA
ROOT CAUSE ANALYSIS
Fishbone Analysis - Weld Penetration
Weld penetration below the specified requirement
CAPA-2026-0017 · Weld penetration below requirement
Back
Interactive Ishikawa Diagram
Click any cause node to inspect evidence and root-cause status.
Cause
Root cause
CAUSES
Man
Operator adjusted current with…
Machine
Welding controller current dri…
✓
Method
Parameter window was not locked
✓
Material
Material surface condition var…
Measurement
Current verification was perfo…
Environment
Ambient temperature affected p…
PROBLEM
Weld penetration below the …
pecified requirement
Cause Register
Evidence-backed causes identified during analysis
6 causes
Category
Cause
Evidence
Classification
Man
Operator adjusted current without documented escalation
Additional sample evidence for CAPA-2026-0017.
Potential cause
Machine
Welding controller current drift
Additional sample evidence for CAPA-2026-0017.
Root cause
Method
Parameter window was not locked
Additional sample evidence for CAPA-2026-0017.
Root cause
Material
Material surface condition varied
Additional sample evidence for CAPA-2026-0017.
Potential cause
Measurement
Current verification was performed only weekly
Additional sample evidence for CAPA-2026-0017.
Potential cause
Environment
Ambient temperature affected preheat consistency
Additional sample evidence for CAPA-2026-0017.
Potential cause
Add Cause
Feed the graphical analysis directly
Category
Man
Machine
Method
Material
Measurement
Environment
Cause
Evidence / Observation
Confirmed root cause
Add Cause
CATEGORY
Cause
Evidence / Observation
This cause is classified as a confirmed root cause.