QUALITY MANAGEMENT

Fishbone Analysis - Weld Penetration

ROOT CAUSE ANALYSIS

Fishbone Analysis - Weld Penetration

Weld penetration below the specified requirement
Interactive Ishikawa Diagram
Click any cause node to inspect evidence and root-cause status.
Cause Root cause
CAUSES Man Operator adjusted current with… Machine Welding controller current dri… Method Parameter window was not locked Material Material surface condition var… Measurement Current verification was perfo… Environment Ambient temperature affected p… PROBLEM Weld penetration below the … pecified requirement
Cause Register
Evidence-backed causes identified during analysis
6 causes
CategoryCauseEvidenceClassification
Man Operator adjusted current without documented escalation Additional sample evidence for CAPA-2026-0017. Potential cause
Machine Welding controller current drift Additional sample evidence for CAPA-2026-0017. Root cause
Method Parameter window was not locked Additional sample evidence for CAPA-2026-0017. Root cause
Material Material surface condition varied Additional sample evidence for CAPA-2026-0017. Potential cause
Measurement Current verification was performed only weekly Additional sample evidence for CAPA-2026-0017. Potential cause
Environment Ambient temperature affected preheat consistency Additional sample evidence for CAPA-2026-0017. Potential cause
Add Cause
Feed the graphical analysis directly